This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Product headline
std_productprofile_product_usp_34654_1508938758.
Fully suitable for basic applications in the chemical and process industry. -
Sensor features
Cost-effective sensor – ideal solution for basic requirements. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24"). Ex approvals for Zone 2. Liner made of PTFE. -
Transmitter features
std_productprofile_product_benefits_34656_1508940491. std_productprofile_product_benefits_34658_1508940614. std_productprofile_product_benefits_34657_1508940613.
std_successorproducts_product_differentiating_tech_features_35324_1509527963. std_successorproducts_product_differentiating_tech_features_35325_1509527962. std_successorproducts_product_differentiating_tech_features_35326_1509527956. -
Nominal diameter range
DN 15 to 600 (½ to 24")
-
Wetted materials
Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum -
Measured variables
Volume flow
-
Max. measurement error
Volume flow: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
-
Measuring range
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
-
Max. process pressure
PN 40, Class 150, 20K
-
Medium temperature range
–10 to +110 °C (+14 to +230 °F)
-
Ambient temperature range
–10 to +60 °C (+14 to +140 °F)
-
Sensor housing material
DN 15 to 300 (½ to 12"): AlSi10Mg, coated
DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
Sensor connection housing: AlSi10Mg, coated -
Transmitter housing material
Powder‐coated die‐cast aluminum
-
Degree of protection
Compact version: IP67, type 4X enclosure
Sensor remote version (standard): IP67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure
Transmitter remote version: IP67, type 4X enclosure -
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency (passive)
Relay output
Switch output (passive) -
Inputs
2 modular inputs:
Status input
0‐20 mA (aktiv)/4‐20 mA (aktiv/passiv) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, MODBUS RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, cCSAus
-
Product safety
CE, C-tick, EAC marking
-
Metrological approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
-
Pressure approvals and certificates
PED
-
Material certificates
3.1 material
-
-
Installation Instructions (EA)
Replacing amplifier board Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN 15/11/2018Language:
English
Version:
15/11/2018
File size:
393.9 KB
File name:
EA00064DA2_1518.pdf
-
-
-
Installation Instructions (EA)
Replacing amplifier board for harsh environment (HE) Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromag 50, 53, 55, Promass 80, 83, 84, Cubemass DCI 8CN, CNGmass DCI 8DF
EN 15/11/2018Language:
English
Version:
15/11/2018
File size:
379.4 KB
File name:
EA00067DA2_1518.pdf
-
-
-
Installation Instructions (EA)
EA Installing ground disks
-
Installation Instructions (EA)
English version - 10/2025New version available in EnglishPromag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
EN 15/10/202509/10/2020Language:
English
Version:
15/10/2025
File size:
772.1 KB
File name:
EA00070DA2_1625-00.pdf
-