Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10 probe
Developed according to industry standards for single-use sensors, this Raman optic system is cGMP qualified and gamma sterilizable. The system is comprised of two parts - a reusable optic and a disposable fitting for single-use bioreactors (SUB). The Raman optic system for single use in conjunction with the Rxn-10 probe offers the same quality data as reusable Raman probes. This ability allows customers to develop products and processes without limitations of the final production reactor type.
Cell culture: glucose, lactate, amino acids, cell density, titer
Fermentation: glycerol, methanol, ethanol, sorbitol, biomass
Disposable fitting for single-use bioreactors (SUB), plus a non-contact reusable optic
Developed to industry standards for single-use sensors
Gamma sterilizable
Tested and supplied by multiple SUB vendors
Specialized products
Technical excellence
Simplicity
Variable
Standard products
Technical excellence
Simplicity
Specialized products
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
| EN | |||
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
Language: |
English |
|
Version: |
31/05/2023 |
|
File size: |
467.9 KB |
|
File name: |
TI01635CEN_0322.pdf |
System design and specifications for the Raman Rxn-10 probe
| EN | |||
|
08/09/2025
|
|
|
|
|
13/11/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Language: |
English |
|
Version: |
08/09/2025 |
|
File size: |
949 KB |
|
File name: |
TI01629CEN_0525.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
| EN | |||
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Language: |
English |
|
Version: |
31/05/2023 |
|
File size: |
1.8 MB |
|
File name: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
| EN | |||
|
08/09/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Language: |
English |
|
Version: |
08/09/2025 |
|
File size: |
1.8 MB |
|
File name: |
BA02160CEN_0525.pdf |
Quick start guide for the Raman Rxn-10 probe
| EN | |||
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Language: |
English |
|
Version: |
02/12/2024 |
|
File size: |
1.6 MB |
|
File name: |
KA01546CEN_0424.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
| EN | |||
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Language: |
English |
|
Version: |
31/05/2023 |
|
File size: |
1 MB |
|
File name: |
KA01551CEN_0322.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Language: |
English |
|
Version: |
26/06/2025 |
|
File size: |
363.4 KB |
|
File name: |
PU01611CEN_0125.pdf |
Graphic illustrating the core elements of Biopharma 4.0 including
product lifecycle stages, role of PAT/QbD, and 12 key advanced
technologies for scientists and process engineers in the Life
Sciences, applicable to Raman spectroscopy systems (Raman
Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and
sleeve, flow cell and flow bench, Raman optic system for single
use, and Raman calibration & verification kits).
|
Language: |
English |
|
Version: |
22/05/2025 |
|
File size: |
481.6 KB |
|
File name: |
PU01614CEN_0125.pdf |
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。
|
Language: |
Japanese |
|
Version: |
04/10/2024 |
|
File size: |
2.5 MB |
|
File name: |
PU01585CJA_0124_Graphic_EH biopharma trust.pdf |
この製品リストは、ライフサイエンス業界におけるバイオプロセス
用途向けに、光学分析および液体分析の両方から提供される分析機
器をまとめたものです。含まれる製品には、Raman Rxn2アナライザ
、Raman Rxn4アナライザ、Rxn-10プローブ、バイオマルチオプティ
ックおよびバイオスリーブ、ラマンフローアセンブリ、Rxn-45プロ
ーブ、Rxn-46プローブ、シングルユース向けラマンオプティックシ
ステム、Memosens CPS61E、Memosens COS81E、OUSBT66、Memosens
CPS77E、Memosens CLS82E、OUSAF44、Memosens CPS11E、Memosens
CLS16E、TOCアナライザーCA79、Liquiline変換器プラットフォーム
、およびMemobaseソフトウェアが含まれています。
|
Language: |
Japanese |
|
Version: |
24/08/2025 |
|
File size: |
1.2 MB |
|
File name: |
PU01484CJA_0224_Lab-to-Process Control in Life Sciences.pdf |