TÜV type test Suitability tested acc. DIN EN 15267-1 (2009), DIN-EN 15267-2 (2009), DIN EN 15859 (2010), DIN EN 14181 (2014) Certified for use as Dust monitor and Leak monitor for filter control downstream of dust collectors at installations requiring approval (13th BlmSchV, 17th BlmSchV, 27th BlmSchV, 30th BlmSchV, 44th BlmSchV and TA Luft)
The DUSTHUNTER SP30 is a measuring device which reliably detects very low to high dust content. The automated monitoring of the zero and reference point ensures a high level of accuracy. Thanks to its compact design, the DUSTHUNTER SP30 is available as an independent measuring device but also with an integrated purge air unit and MCU control unit for additional functions as an option. Several mounting options and probe lengths are available.
Emission monitoring which does not require permission in industrial systems
Monitoring of cloth filters for defective filter bags
Dust monitoring in grinding and dosing systems
Dust concentration measurements in exhaust gas ducts
Device properties:
Independent measuring device – with or without MCU control unit
Automated monitoring of zero and reference point
Integrated purge air unit as an option
Installation on one side of a duct
Rugged and compact structure
No moving parts in the duct
Benefits
Accurate dust measurement – independently of gas velocity or particle charge
Convenient data transmission via Modbus® and analog output directly from the sensor
Versatile thanks to several configurable measuring ranges
Two calibration curves for switching with different dust sources
No external purge air unit required as it is integrated into the device (option)
High degree of flexibility due to different mounting options
With intergrated purge air unit: –50 hPa ... 10 hPa With external purge air unit: –50 hPa ... 30 hPa With instrument air (provided by the customer) –50 hPa ... 100 hPa
Ambient temperature range
–40 °C ... +60 °C
Process gas humidity
Non-condensing
Degree of protection
IP66/IP54 (without/with integrated purge air unit)
Conformities
TÜV type test Suitability tested acc. DIN EN 15267-1 (2009), DIN-EN 15267-2 (2009), DIN EN 15859 (2010), DIN EN 14181 (2014) Certified for use as Dust monitor and Leak monitor for filter control downstream of dust collectors at installations requiring approval (13th BlmSchV, 17th BlmSchV, 27th BlmSchV, 30th BlmSchV, 44th BlmSchV and TA Luft)
Emission Monitoring Solutions – broad instrument portfolio and
longstanding experience
Competence Brochure (CP)
English version - 01/2025
New version available in English
An overview brochure about emission monitoring, their measuring principles and technologies, global requirements and services, a selection guide and the measuring devices at a glance