Specs at a glance
-
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r. -
Measuring range
Gas: 0.3 m/s to 40 m/s
-
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell -
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
-
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2
Field of application
For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.
The measuring principle is unaffected by gas composition
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Device properties:
Direct measurement: flow, pressure & temperature
Wetted parts: titanium / 316L
Maximum measuring accuracy: 0.5 %
Compact dual-compartment housing with up to 3 I/Os
Backlit display with touch control and WLAN access
Remote display available
Benefits
Flexible device with user-definable gas mixtures for demanding measuring tasks
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate
High-performance process control – real-time pressure- and temperature-compensated values
Efficient solution – multivariable, no pressure loss
Full access to process and diagnostic information – numerous, freely combinable I/Os
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Proline Prosonic Flow G 300 Technical Information
English version - 09/2019
Ultrasonic time-of-flight flowmeter Highly robust gas specialist for fluctuating conditions with compact, easily accessible transmitter
EN 16/09/201905/08/2019Language:
English
Version:
16/09/2019
File size:
5.8 MB
File name:
TI01385DEN_0219.pdf
-
-
-
Short Instruction (KA)
Proline Prosonic Flow G Brief Operating Instructions
English version - 08/2019
Proline Prosonic Flow G Ultrasonic time-of-flight sensor
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
792.2 KB
File name:
KA01374DEN_0119.pdf
-
-
-
Technical Information (TI)
Proline Prosonic Flow G 300 Technical Information
Ultrasonic time-of-flight flowmeter Highly robust gas specialist for fluctuating conditions with compact, easily accessible transmitter
EN 16/09/201905/08/2019Language:
English
Version:
16/09/2019
File size:
5.8 MB
File name:
TI01385DEN_0219.pdf
-
-
-
Operating Instruction (BA)
Proline Prosonic Flow G 300 Modbus RS485 Operating Instructions
Ultrasonic time-of-flight flowmeter
EN 16/09/201905/08/2019Language:
English
Version:
16/09/2019
File size:
7.4 MB
File name:
BA01835DEN_0219.pdf
-
-
-
Operating Instruction (BA)
Proline Prosonic Flow G 300 HART Operating Instructions
Ultrasonic time-of-flight flowmeter
EN 16/09/201905/08/2019Language:
English
Version:
16/09/2019
File size:
8.2 MB
File name:
BA01834DEN_0219.pdf
-
-
-
Device Parameter (GP)
Proline Prosonic Flow 300 HART Description of Device Parameters
Ultrasonic time-of-flight flowmeter
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
2.1 MB
File name:
GP01130DEN_0119.pdf
-
-
-
Device Parameter (GP)
Proline Prosonic Flow 300 Modbus RS485 Description of Device Parameters
Ultrasonic time-of-flight flowmeter
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
2.3 MB
File name:
GP01131DEN_0119.pdf
-
-
-
Short Instruction (KA)
Proline 300 HART Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
1.6 MB
File name:
KA01375DEN_0119.pdf
-
-
-
Short Instruction (KA)
Proline Prosonic Flow G Brief Operating Instructions
Proline Prosonic Flow G Ultrasonic time-of-flight sensor
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
792.2 KB
File name:
KA01374DEN_0119.pdf
-
-
-
Short Instruction (KA)
Proline 300 Modbus RS485 Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
1.8 MB
File name:
KA01376DEN_0119.pdf
-
-
-
Installation Instructions (EA)
Alteration to Display module, to Display module with WirelessHART or Display module with WLAN
Promag, Promass, Prosonic Flow 300, 500, 500-digital, t-mass 300, 500-digital
EN 01/08/202131/07/202002/08/201902/01/201902/05/2018Language:
English
Version:
01/08/2021
File size:
1.4 MB
File name:
EA01158DA2_0721.pdf
-
-
-
Installation Instructions (EA)
Replacing the electronics
Promag, Promass, Prosonic Flow 300, 500, 500-digital, t-mass 300, 500-digital
EN 01/06/202131/07/202002/08/201902/01/201901/06/2018Language:
English
Version:
01/06/2021
File size:
1 MB
File name:
EA01145DA2_0621.pdf
-
-
Kit power supply, 100-230VAC, Ex
-
Power supply
Drawing numberOrder code3171323007 -
-
Kit power supply, 24VDC, Ex
-
Power supply
Drawing numberOrder code3171323008 -
-
Kit pow.supply,100-230VAC/24VDC, Non-haz
-
Power supply
Drawing numberOrder code3171323009 -
-
ISEM electr.mod.,Prosonic Flow G 300/500
-
Electronic
Drawing numberOrder code33XPD0048- -
-
Kit T-DAT, 100/300/400/500/500 digital
-
Memory
Drawing numberOrder code3971185788 -
-
I/O module, slot 1, 300/500
-
I/O module
Drawing numberOrder code34XPD0037- -
-
Kit module cartridge, 300/500, Ex
-
Electronic (periphery)
Drawing numberOrder code3771323010 -
-
Kit module cartridge, 300/500, Non-haz
-
Electronic (periphery)
Drawing numberOrder code3771323011 -
-
I/O module, slot 2/3/4, 300/500
-
I/O module
Drawing numberOrder code35XPD0038- -
-
Kit ISEM ribbon cable, 300/500
-
Connection (electrical)
Drawing numberOrder code4671459751 -
-
Display module, 300/500/DKX001
-
Display
Drawing numberOrder code50XPD0031- -
-
Kit conn.terminal option A,300/500,N-haz
-
Terminal module
Drawing numberOrder code4571323073 -
-
Kit conn.terminal option C,300/500,N-haz
-
Terminal module
Drawing numberOrder code4571327818 -
-
Kit conn.terminal option A, 300/500, Ex
-
Terminal module
Drawing numberOrder code4571323075 -
-
Kit conn.terminal option C, 300/500, Ex
-
Terminal module
Drawing numberOrder code4571327819 -
-
Kit conn.terminal option A, 300/500, Ex
-
Terminal module
Drawing numberOrder code4571323075 -
-
Kit conn.terminal option C, 300/500, Ex
-
Terminal module
Drawing numberOrder code4571327819 -
-
Kit terminal, transm.,remote display,300
-
Terminals
Drawing numberOrder code4971323079 -
-
Kit cover, sight glass, Alu,Non-haz/Exde
-
Cover
Drawing numberOrder code2071323016 -
-
Kit cover,glass, Alu, -50oC,Non-haz/Exde
-
Cover
Drawing numberOrder code2071323017 -
-
Kit cover, blind, Alu, Non-haz/Exde
-
Cover
Drawing numberOrder code2171323018 -
-
Kit cover, blind, Alu,-50oC,Non-haz/Exde
-
Cover
Drawing numberOrder code2171323019 -
-
Kit cover, sight glass, Alu, Exd
-
Cover
Drawing numberOrder code2071323020 -
-
Kit cover, sight glass, Alu, -50oC, Exd
-
Cover
Drawing numberOrder code2071323021 -
-
Kit cover, blind, Alu, Exd
-
Cover
Drawing numberOrder code2171323022 -
-
Kit cover, blind, Alu, -50oC, Exd
-
Cover
Drawing numberOrder code2171323023 -
-
Kit cover, sight glass, cast, Ex
-
Cover
Drawing numberOrder code2071323024 -
-
Kit cover, sight glass, cast, -50oC, Ex
-
Cover
Drawing numberOrder code2071323025 -
-
Kit cover, blind, cast, Ex
-
Cover
Drawing numberOrder code2171327102 -
-
Kit cover, blind, cast, -50oC, Ex
-
Cover
Drawing numberOrder code2171327103 -
-
Kit cover gasket, sight glass/blind
-
Sealing
Drawing numberOrder code7071323026 -
-
Kit cover gasket,sight glass/blind,-50oC
-
Sealing
Drawing numberOrder code7071323027 -
-
Kit cover, electr.compart., Alu, Non-haz
-
Cover
Drawing numberOrder code2271323028 -
-
Kit cover,electronic, Alu,- 50oC,Non-haz
-
Cover
Drawing numberOrder code2271323029 -
-
Kit cover gasket,electr.compart.,Non-haz
-
Sealing
Drawing numberOrder code7471323030 -
-
Kit cover gasket,electr., -50oC, Non-haz
-
Sealing
Drawing numberOrder code7471323031 -
-
Kit cover, electronic compart., Alu, Ex
-
Cover
Drawing numberOrder code2271323032 -
-
Kit cover, electr.compart., Alu,-50oC,Ex
-
Cover
Drawing numberOrder code2271323033 -
-
Kit cover, electronic compart., cast, Ex
-
Cover
Drawing numberOrder code2271323034 -
-
Kit cover, electr.compart.,cast,-50oC,Ex
-
Cover
Drawing numberOrder code2271323035 -
-
Kit cover gasket, electronic compart.,Ex
-
Sealing
Drawing numberOrder code7471323036 -
-
Kit cover gasket,elect.compart.,-50oC,Ex
-
Sealing
Drawing numberOrder code7471323037 -
-
Kit cover gasket, electronic compart.,Ex
-
Sealing
Drawing numberOrder code7471323036 -
-
Kit cover gasket,elect.compart.,-50oC,Ex
-
Sealing
Drawing numberOrder code7471323037 -
-
Kit cover, remote display, Alu
-
Cover
Drawing numberOrder code2871323044 -
-
Kit cover, remote display, Alu, -50oC
-
Cover
Drawing numberOrder code2871323045 -
-
Kit cover, remote display, cast
-
Cover
Drawing numberOrder code2871323046 -
-
Kit cover, remote display, cast, -50oC
-
Cover
Drawing numberOrder code2871323047 -
-
Kit cover gasket, remote display
-
Sealing
Drawing numberOrder code7671323048 -
-
Kit cover gasket, remote display, -50oC
-
Sealing
Drawing numberOrder code7671323049 -
-
Kit interface gaskets, 300/500
-
Sealing
Drawing numberOrder code7171323071 -
-
Kit interface gaskets, 300/500, -50oC
-
Sealing
Drawing numberOrder code7171323072 -
-
Kit protect.cover option A,300/500,N-haz
-
Miscellaneous
Drawing numberOrder code1171368488 -
-
Kit protective cover option A,300/500,Ex
-
Miscellaneous
Drawing numberOrder code1171323081 -
-
Kit protective cover option A,300/500,Ex
-
Miscellaneous
Drawing numberOrder code1171323081 -
-
Spare RFID TAG
-
further parts
Order codeXPRFID- -
-
Kit weather protection cover, 300/500
Drawing numberOrder code8771343505 -
Kit wireless antenna extended range
Order code71351317 -
Transmitter Prosonic Flow 300, 9X3BXX
Order code9X3BXX- -
Remote Display DKX001
Order codeDKX001- -
Connection Cable for Remote Display
Order codeDKX002-