Specs at a glance
-
Max. measurement error
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
-
Measuring range
0.5 to 3750 kg/h (1.1 to 8250 lb/h)
-
Medium temperature range
-40 °C to +180°C (-40 °F to +356 °F)
-
Max. process pressure
PN40 / Cl. 300 / 20K
-
Wetted materials
Measuring tubes
DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408
DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections
Stainless steel, 1.4404 (F316/F316L)
Threaded connections
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
Field of application
The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. Its compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures measurement reliability and compliant verification.
Measuring principle is characterized by a high operable flow range and direct mass flow measurement
Measurement of utility and process gases as well as gas mixtures in small line sizes
Device properties
Inline version with DN 15 to 100 (1/2 to 4")
Bidirectional measurement; high measuring performance
Patented drift-free sensor with SIL 2
Compact dual-compartment housing with up to 3 I/Os
Backlit display with touch control and WLAN access
Remote display available
Benefits
Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
High level of process control – premium measurement accuracy and repeatability
Reliable monitoring – detection of process disturbances and reverse flow
Easy maintenance – removable sensor
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Proline t-mass F 300
English version - 07/2021
Thermal mass flowmeter
EN 05/07/202117/09/2020Language:
English
Version:
05/07/2021
File size:
5.4 MB
File name:
TI01500DEN_0221.pdf
-
-
-
Operating Instruction (BA)
Proline t-mass F 300 Modbus RS485
English version - 07/2021
Thermal mass flowmeter
EN 05/07/202117/09/2020Language:
English
Version:
05/07/2021
File size:
6.7 MB
File name:
BA01994DEN_0221.pdf
-
-
-
Technical Information (TI)
Proline t-mass F 300
Thermal mass flowmeter
EN 05/07/202117/09/2020Language:
English
Version:
05/07/2021
File size:
5.4 MB
File name:
TI01500DEN_0221.pdf
-
-
-
Operating Instruction (BA)
Proline t-mass F 300 Modbus RS485
Thermal mass flowmeter
EN 05/07/202117/09/2020Language:
English
Version:
05/07/2021
File size:
6.7 MB
File name:
BA01994DEN_0221.pdf
-
-
-
Operating Instruction (BA)
Proline t-mass F 300 HART
Thermal mass flowmeter
EN 05/07/202117/09/2020Language:
English
Version:
05/07/2021
File size:
7.6 MB
File name:
BA01992DEN_0221.pdf
-
-
-
Device Parameter (GP)
Proline t-mass 300 HART
Thermal mass flowmeter
EN 01/07/202117/09/2020Language:
English
Version:
01/07/2021
File size:
2.1 MB
File name:
GP01143DEN_0221.pdf
-
-
-
Device Parameter (GP)
Proline t-mass 300 Modbus RS485
Thermal mass flowmeter
EN 01/07/202117/09/2020Language:
English
Version:
01/07/2021
File size:
2.2 MB
File name:
GP01144DEN_0221.pdf
-
-
-
Short Instruction (KA)
Proline 300 Modbus RS485
Transmitter with thermal mass flow sensor
EN 05/07/202117/09/2020Language:
English
Version:
05/07/2021
File size:
2 MB
File name:
KA01445DEN_0221.pdf
-
-
-
Short Instruction (KA)
Proline 300 HART
Transmitter with thermal mass flow sensor
EN 05/07/202117/09/2020Language:
English
Version:
05/07/2021
File size:
1.9 MB
File name:
KA01444DEN_0221.pdf
-
-
-
Short Instruction (KA)
Proline t-mass F
Thermal mass flow sensor
EN 05/07/202117/09/2020Language:
English
Version:
05/07/2021
File size:
925.3 KB
File name:
KA01442DEN_0221.pdf
-
-
-
Installation Instructions (EA)
Alteration to Display module, to Display module with WirelessHART or Display module with WLAN
Promag, Promass, Prosonic Flow 300, 500, 500-digital, t-mass 300, 500-digital
EN 01/08/202131/07/202002/08/201902/01/201902/05/2018Language:
English
Version:
01/08/2021
File size:
1.4 MB
File name:
EA01158DA2_0721.pdf
-
-
-
Installation Instructions (EA)
Replacing the electronics
Promag, Promass, Prosonic Flow 300, 500, 500-digital, t-mass 300, 500-digital
EN 01/06/202131/07/202002/08/201902/01/201901/06/2018Language:
English
Version:
01/06/2021
File size:
1 MB
File name:
EA01145DA2_0621.pdf
-
-
Kit power supply, 100-230VAC, Ex
-
Power supply
Drawing numberOrder code3171323007 -
-
Kit power supply, 24VDC, Ex
-
Power supply
Drawing numberOrder code3171323008 -
-
Kit pow.supply,100-230VAC/24VDC, Non-haz
-
Power supply
Drawing numberOrder code3171323009 -
-
ISEM electr.mod., t-mass 300/500 digital
-
Electronic
Drawing numberOrder code33XPD0052- -
-
Kit T-DAT, 100/300/400/500/500 digital
-
Memory
Drawing numberOrder code3971185788 -
-
ISEM electr.mod., t-mass 300
-
Electronic
Drawing numberOrder code33XPD0053- -
-
Kit module cartridge, 300/500, Ex
-
Electronic (periphery)
Drawing numberOrder code3771323010 -
-
I/O module, slot 1, 300/500
-
I/O module
Drawing numberOrder code34XPD0037- -
-
Kit module cartridge, 300/500, Non-haz
-
Electronic (periphery)
Drawing numberOrder code3771323011 -
-
Kit ISEM ribbon cable, 300/500
-
Connection (electrical)
Drawing numberOrder code4671323005 -
-
I/O module, slot 2/3/4, 300/500
-
I/O module
Drawing numberOrder code35XPD0038- -
-
Kit conn.terminal option A,300/500,N-haz
-
Terminal module
Drawing numberOrder code4571323073 -
-
Display module, 300/500/DKX001
-
Display
Drawing numberOrder code50XPD0031- -
-
Kit conn.terminal option C,300/500,N-haz
-
Terminal module
Drawing numberOrder code4571327818 -
-
Kit conn.terminal option A, 300/500, Ex
-
Terminal module
Drawing numberOrder code4571323075 -
-
Kit conn.terminal option C, 300/500, Ex
-
Terminal module
Drawing numberOrder code4571327819 -
-
Kit terminal, transm.,remote display,300
-
Terminals
Drawing numberOrder code4971323079 -
-
Kit cover, sight glass, Alu,Non-haz/Exde
-
Cover
Drawing numberOrder code2071323016 -
-
Kit cover,glass, Alu, -50oC,Non-haz/Exde
-
Cover
Drawing numberOrder code2071323017 -
-
Kit cover, blind, Alu, Non-haz/Exde
-
Cover
Drawing numberOrder code2171323018 -
-
Kit cover, blind, Alu,-50oC,Non-haz/Exde
-
Cover
Drawing numberOrder code2171323019 -
-
Kit cover, sight glass, Alu, Exd
-
Cover
Drawing numberOrder code2071323020 -
-
Kit cover, sight glass, Alu, -50oC, Exd
-
Cover
Drawing numberOrder code2071323021 -
-
Kit cover, blind, Alu, Exd
-
Cover
Drawing numberOrder code2171323022 -
-
Kit cover, blind, Alu, -50oC, Exd
-
Cover
Drawing numberOrder code2171323023 -
-
Kit cover gasket, sight glass/blind
-
Sealing
Drawing numberOrder code7071323026 -
-
Kit cover gasket,sight glass/blind,-50oC
-
Sealing
Drawing numberOrder code7071323027 -
-
Kit cover, electr.compart., Alu, Non-haz
-
Cover
Drawing numberOrder code2271323028 -
-
Kit cover,electronic, Alu,- 50oC,Non-haz
-
Cover
Drawing numberOrder code2271323029 -
-
Kit cover gasket,electr.compart.,Non-haz
-
Sealing
Drawing numberOrder code7471323030 -
-
Kit cover gasket,electr., -50oC, Non-haz
-
Sealing
Drawing numberOrder code7471323031 -
-
Kit cover, electronic compart., Alu, Ex
-
Cover
Drawing numberOrder code2271323032 -
-
Kit cover, electr.compart., Alu,-50oC,Ex
-
Cover
Drawing numberOrder code2271323033 -
-
Kit cover gasket, electronic compart.,Ex
-
Sealing
Drawing numberOrder code7471323036 -
-
Kit cover gasket,elect.compart.,-50oC,Ex
-
Sealing
Drawing numberOrder code7471323037 -
-
Kit cover, remote display, Alu
-
Cover
Drawing numberOrder code2871323044 -
-
Kit cover, remote display, Alu, -50oC
-
Cover
Drawing numberOrder code2871323045 -
-
Kit cover gasket, remote display
-
Sealing
Drawing numberOrder code7671323048 -
-
Kit cover gasket, remote display, -50oC
-
Sealing
Drawing numberOrder code7671323049 -
-
Kit interface gaskets, 300/500
-
Sealing
Drawing numberOrder code7171323071 -
-
Kit interface gaskets, 300/500, -50oC
-
Sealing
Drawing numberOrder code7171323072 -
-
Kit protect.cover option A,300/500,N-haz
-
Miscellaneous
Drawing numberOrder code1171368488 -
-
Kit protective cover option A,300/500,Ex
-
Miscellaneous
Drawing numberOrder code1171323081 -
-
Spare RFID TAG
-
further parts
Order codeXPRFID- -
-
Kit weather protection cover, 300/500
Drawing numberOrder code8771343505 -
Kit wireless antenna extended range
Order code71351317 -
Transmitter t-mass 300, 6X3BXX
Order code6X3BXX- -
Remote Display DKX001
Order codeDKX001- -
Connection Cable for Remote Display
Order codeDKX002-