Specs at a glance
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F) -
Max. process pressure
PN 63, Class 300, 40K
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Field of application
Promass P 100 offers the enhanced performance of a bent tube meter and the drainability of a straight tube meter without any compromise. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Designed for applications in sterile environments where space is a premium, Promass P 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Dedicated for applications under sterile conditions in the life sciences industry.
Device properties
ASME BPE, 3-A and EHEDG conform & low delta ferrite
Electropolished measuring tube in 1.4435 (316L)
Fast recovery from CIP/SIP
Robust, ultra-compact transmitter housing
High ingress protection: IP69K
Local display available
Benefits
Highest process quality – fully compliant to industry requirements
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in/outlet run needs
Space-saving transmitter – full functionality on smallest footprint
Time-saving local operation without additional software and hardware – integrated web server
Integrated verification – Heartbeat Technology
Videos
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Proline Promass P 100 Technical Information
English version - 12/2015
Coriolis flowmeter Specialist for life sciences with an ultra-compact transmitter
EN 01/12/201510/06/201419/09/201301/04/201301/06/2012Language:
English
Version:
01/12/2015
File size:
2.9 MB
File name:
TI01036DEN_0515.pdf
-
-
-
Operating Instruction (BA)
Proline Promass P 100 EtherNet/IP Operating Instructions
English version - 12/2014
Coriolis flowmeter
EN 31/12/201401/04/201301/06/2012Language:
English
Version:
31/12/2014
File size:
4.2 MB
File name:
BA01067DEN_0314.pdf
-
-
-
Technical Information (TI)
Proline Promass P 100 Technical Information
Coriolis flowmeter Specialist for life sciences with an ultra-compact transmitter
EN 01/12/201510/06/201419/09/201301/04/201301/06/2012Language:
English
Version:
01/12/2015
File size:
2.9 MB
File name:
TI01036DEN_0515.pdf
-
-
-
Operating Instruction (BA)
Proline Promass P 100 PROFINET Operating Instructions
Coriolis flowmeter
EN 01/12/2015Language:
English
Version:
01/12/2015
File size:
3.1 MB
File name:
BA01431DEN_0115.pdf
-
-
-
Operating Instruction (BA)
Proline Promass P 100 HART Operating Instructions
Coriolis flowmeter
EN 10/06/201401/04/2013Language:
English
Version:
10/06/2014
File size:
3.9 MB
File name:
BA01192DEN_0214.pdf
-
-
-
Operating Instruction (BA)
Proline Promass P 100 PROFIBUS DP Operating Instructions
Coriolis flowmeter
EN 31/12/201419/09/2013Language:
English
Version:
31/12/2014
File size:
4.4 MB
File name:
BA01253DEN_0214.pdf
-
-
-
Operating Instruction (BA)
Proline Promass P 100 EtherNet/IP Operating Instructions
Coriolis flowmeter
EN 31/12/201401/04/201301/06/2012Language:
English
Version:
31/12/2014
File size:
4.2 MB
File name:
BA01067DEN_0314.pdf
-
-
-
Operating Instruction (BA)
Proline Promass P 100 Modbus RS485 Operating Instructions
Coriolis flowmeter
EN 01/04/201301/06/2012Language:
English
Version:
01/04/2013
File size:
2.9 MB
File name:
BA01059DEN_0213.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 Modbus RS485 Description of Device Parameters
Coriolis flowmeter
EN 01/10/201723/12/2015Language:
English
Version:
01/10/2017
File size:
1 MB
File name:
GP01035DEN_0217.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 EtherNet/IP Description of Device Parameters
Coriolis flowmeter
EN 01/10/201723/12/2015Language:
English
Version:
01/10/2017
File size:
1.5 MB
File name:
GP01036DEN_0217.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 PROFIBUS DP Description of Device Parameters
Coriolis flowmeter
EN 01/10/201701/12/2015Language:
English
Version:
01/10/2017
File size:
1.7 MB
File name:
GP01034DEN_0217.pdf
-
-
-
Device Parameter (GP)
Proline Promass 100 HART Description of Device Parameters
Coriolis flowmeter
EN 01/10/201701/12/2015Language:
English
Version:
01/10/2017
File size:
1.9 MB
File name:
GP01033DEN_0217.pdf
-
-
Kit Ex-i barrier
-
Electronic (periphery)
Drawing numberOrder code4771185785 -
-
Kit connection terminal for Ex-i barrier
-
Terminals
Drawing numberOrder code4571185787 -
-
Electronic Promass/Cubemass 100
-
Electronic
Drawing numberOrder code30XPD0005- -
-
Kit T-DAT, 100/300/400/500/500 digital
-
Memory
Drawing numberOrder code3971185788 -
-
Display module, 4-wire, 100
-
Display
Drawing numberOrder code50XPD0023- -
-
Kit cover, compact, Alu
-
Cover
Drawing numberOrder code2171185789 -
-
Kit cover, compact, stainless 1.4301
-
Cover
Drawing numberOrder code2171185790 -
-
Kit cover,ultra compact,stainless 1.4301
-
Cover
Drawing numberOrder code2171185793 -
-
Kit cover, sight glass, compact, Alu
-
Cover
Drawing numberOrder code2071266334 -
-
Kit cover, sight glass, compact, 1.4301
-
Cover
Drawing numberOrder code2071266335 -
-
Kit cover,sight glass,ultra comp.,1.4301
-
Cover
Drawing numberOrder code2071266337 -
-
Kit housing gaskets, compact, Alu
-
Sealing
Drawing numberOrder code7071185795 -
-
Kit housing gaskets, compact, stainless
-
Sealing
Drawing numberOrder code7071185797 -
-
Kit hous.gaskets,ultra compact,stainless
-
Sealing
Drawing numberOrder code7071185799 -
-
Kit 10 cable glands M20x1.5 Ex
-
Adapter housing/cable entry
Drawing numberOrder code1550098036 -
-
Kit 2 cable glands M20x1.5 INOX Ex
-
Adapter housing/cable entry
Drawing numberOrder code1571069285 -
-
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Adapter housing/cable entry
Drawing numberOrder code1550098041 -
-
Kit 2 cable glands G1/2" INOX Ex
-
Adapter housing/cable entry
Drawing numberOrder code1571185802 -
-
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Adapter housing/cable entry
Drawing numberOrder code1550098042 -
-
Kit 2 cable glands NPT1/2" INOX Ex
-
Adapter housing/cable entry
Drawing numberOrder code1571185800 -
-
Kit securing clamp, screw
-
Housing/housing accessories
Drawing numberOrder code1271276494 -
-
Spare RFID TAG
-
further parts
Order codeXPRFID- -
-
Promass sensor, heating jacket, DK8003